tài liệu kỹ thuật trạm biến áp hộp bộ phần 3 - Pdf 20

ICEBERG
1 module
DESIGN
> Reinforced concrete
monobloc enclosure
> Integrated ventilation
> Access by trap door & ladder
ELECTRICAL CHARACTERISTICS
> Up to 24kV RMU
> Low voltage with
or without metering panel
> Remote control
or fault indicator facilities
ICEBERG
SEMI-UNDERGROUND
with ventilation
DESIGN
> Reinforced concrete
monobloc enclosure
> Integrated ventilation
> Access by trap door
ELECTRICAL CHARACTERISTICS
> Up to 36kV RMU
> Transformer up to 630kVA
(up to 1000kVA consult us)
> Low voltage with
or without metering panel
> Remote control
or fault indicator facilities
ICEBERG SUB
submersible with

3
1
2460
4260
2335
4260
2335
600
2460
2460
4260
2335 600
1 - MV cubicles
2 - MV/LV Transformer
3 - Low voltage
4 - Remote control
Dimensions in millimetres
21
Iceberg underground Iceberg semi-underground Iceberg submerged
Underground substation - Iceberg
Reinforced concrete
2335 2300
2300
2300
2335
2335
2460
2460
3100 3100 3100
2460

interchangeability and
ease of operation.
Furthermore the TETRIS model
reduces noise and E.M.I.
OPERATOR SAFETY
The retention tank is designed to
canalise and cool gases in case of
any internal arcing.
The access to any danger zone has
an IP2X degree of protection rating.
The complete product is cabled
and tested at the factory by an
industrial process.
A system of self-extinguishing
gratings integrated into the tank,
avoids any incident of fire.
MODULARITY
To be able to adapt to different
types of building the Low Voltage
switchboard can be placed in a
variety of arrangements.
AVANTAGES
> Saving both time and money.
> Saving space inside buildings
(compact),
> Rapid just-in-time delivery,
> Easy and convenient commissio-
ning thanks to the "ready to plug
concept",
> Integrated wheels,

Technical characteristics
>> Compact and modular MV switchgear kV 12 24 36
>> Transformer under 410V power kVA 1000 1000 1000
>> Low voltage protection Fuses or Circuit Breaker
>> Options Remote control - Fault indicator - Panel for internal lighting
Box for public lighting - Access doors - Ventilation grids - Technical - Posters
VERSION 5.5kV - 20kV
WITH FLUOKIT
VERSION 36KV,
WITH FBE
VERSION 10 - 20KV,
WITH FBX
HV
LV
HV
LV
LV
HV
HVLV
LV
HV
HV
HV
HV
OPTION
1 - Medium Voltage cubicle
2 - Transformer (MV/LV)

temporary supply.
CLIPPER M PAP
DESIGN
> Metal enclosure mounted on
a trailer.
E
LECTRICAL CHARACTERISTICS
> MV cubicles up to 36kV,
> Transformer from 250 to 630kVA.
OPTIONS
> MV/MV flexible cables,
> MV and LV cables are available
on roller support, ready to be
connected to the network.
D
ESIGN
> Metal enclosure,
> Street design,
> On skids,
> Mobile kiosk,
> On trailer or carrier.
> Container structure is
self-supporting.
M
AIN ELECTRICAL APPLICATIONS
Mobile MV/LV substations are
used for temporary supply, mainly
refurbishment of a substation,
upgrade of networks, or client
service continuity in case of

(oil or dry transformer),
> Low voltage depending on
specifications.
CLIPPER M 33/11
DESIGN
> Primary HV/MV substation
on a trailer for 33kV/11kV supply.
M
AIN ELECTRICAL APPLICATIONS
A temporary HV/MV power supply
substation is a flexible solution in
case of current breakdown,
to maintain power supply, or the
refurbishment of a power network.
It allows for rapid re-supply
of current.
ELECTRICAL CHARACTERISTICS
> 33kV/11kV network applications,
> Transformer from 2 to 20MVA,
> MV cubicles from 6.6kV to 36kV
A.I.S. or G.I.S. design.
1 - MV cubicles
2 - MV/LV Transformer
3 - Low voltage
4 - Remote control
Dimensions in millimetres
25
Mobile substation - Clipper M
Metal
1

boards up to 20kV or 36kV
(The number of functions
depends on cubicle dimensions),
> Low voltage with or without
metering panel,
> Remote control or
fault indicator facilities
O
PTION
> Aesthetic cover.
DESIGN
Used for large projects for both
industrial and utility applications.
The MV equipment can either be
metal-clad, withdrawable or GIS.
This design concept has been
developed for heavy industrial
projects or MV/MV utility substations.
M
AIN ELECTRICAL APPLICATIONS
> Primary MV/MV substations,
> Large industrial projects MV/LV
(3MVA transformer),
> Diesel generator group (2MVA),
> Wind farms,
> Railways, etc.
Industrial substation - CONCERTO
Reinforced concrete
Industrial substations
26

1
2720
2720
1 - MV cubicles
2 - MV/LV Transformer
3 - Low voltage
4 - Remote control
Dimensions in millimetres
SPACIO substations are very wide, 3800mm, please consult us
27
Outdoor dimensions in mm Indoor dimensions in mm
Lenght. Width Total height Total height Lenght Width Total height Weight
L W above ground H L W under roof in Tons
Type Stand. Spec. Stand. Spec. Stand. Spec.
>> CONCERTO 3 3260 2460 2620 2920 3220 3520 3100 2300 2320 2620 13,5 14,1
CONCERTO 3L 3260 2460 2620 2920 3220 3520 3100 2720 2320 2620 13,5 14,1
>> CONCERTO 4 4260 2530 2620 2920 3220 3520 4060 2330 2320 2620 16,4 17,4
CONCERTO 4L 4260 2940 2950 2920 3550 3520 4060 2740 2320 2620 17,9 18,8
>> CONCERTO 5 5260 2530 2620 2920 3220 3520 5060 2330 2320 2620 20,2 21,2
CONCERTO 5L 5260 2940 2950 2920 3550 3520 5060 2740 2320 2720 21,8 22,9
>> CONCERTO 6 6260 2530 2620 2920 3220 3520 6060 2330 2320 2620 23 24,3
CONCERTO 6L 6260 2940 2950 2920 3550 3520 6060 2740 2320 2620 24,8 26,1
>> CONCERTO 7 7260 2530 2620 2920 3220 3520 7060 2330 2320 2620 26 30,1
CONCERTO 7L 7260 2940 2950 2920 3550 3520 7060 2740 2320 2620 28,7 32,1
>> CONCERTO 8 8260 2530 2620 2920 3220 3520 8060 2330 2320 2620 29,3 30,9
CONCERTO 8L 8260 2940 2950 2920 3550 3520 8060 2740 2320 2620 31,5 33,1
>> CONCERTO 9 9260 2530 2620 2920 3220 3520 9060 2330 2320 2620 32,5 34,2
CONCERTO 9L 9260 2940 2950 2920 3550 3520 9060 2740 2320 2620 34,9 36,6
>> CONCERTO 10 10260 2530 2620 2920 3220 3520 10060 2330 2320 2620 35,3 37,1
CONCERTO 10L 10260 2940 2950 2920 3550 3520 10060 2740 2320 2620 37,9 39,7

requirements (Marine, rail, road,
etc) the use of “metal” remains a
standard reference solution.
Our basic solutions are based on
standardised transport
dimensions, mainly 20’ or
40‘ containers or shelters.
With their modular design, this
solution adapts itself well to
projects that necessitate
electrical switchgear with large
dimensions, the shelter is
therefore made to measure.
OPTION
> Thermal insulation,
> Possibility of applying air
conditioning to the most
exposed areas
> Double roof solution
> Aluminium material
DESIGN
> Casing in painted galvanised
sheet steel, with self-carrying
structures.
> Use of a skid or a frame for their
installation on civil engineering
structures.
MAIN ELECTRICAL APPLICATIONS
Integration of all types of equipment:
> MV switchboards up to 36kV,

5
2
1
2
3
1
2
1
2
3
1
2
3
1
5
22
3
3
WHEN TRANSPORTATION
IS A KEY ISSUE
Container enclosures or concrete
enclosures. Our substations are
designed to receive metal-clad
switchboards with withdrawable
circuit breaker or a G.I.S. switch-
boards up to 40kV. Our range has
been specially designed to fit
marine transportation in order to
reduce costs and handling risks.
ADVANTAGES

ISO corners.
OPTION
> ISO 668 Standard,
> Structure of the container is
U.I.C. and C.S.C. approved
for maritime transport,
> Thermal insulation,
> Air conditioned,
> M0 Fire Protection
rating classification.


Nhờ tải bản gốc

Tài liệu, ebook tham khảo khác

Music ♫

Copyright: Tài liệu đại học © DMCA.com Protection Status