KRONE Premis
NET
HIGHWIRE BRONZE C5e FTP 24AWG 4 Pair CM Solid
Part No : 6499 1 023-03
Standard * UL444, 1581, CSA C22.2 No. 03-92
* ANSI/TIA/EIA-568-A
* ISO/IEC 11801
* EN 50173, 3rd Party ( 3 P )
Application For audio,video and data transfer for local area
network.
* 10 BaseT (IEEE 802.3)
* Fast Ethernet (IEEE 802.3u)
* 100Vg-AnyLAN (IEEE 802.12)
* Token Ring (IEEE 802.5)
* TP-PMD (ANSI X3T9.5)
* 100 Mbps CDDI
* ATM 622
* Gigabit Ethernet (IEEE 802.3z )
Marking KRONE PREMISNET HIGHWIRE BRONZE FTP PART NO : 6499 1 023-03
4PR 24AWG 75 DEGREE CM (UL) VERIFIED TO ISO/IEC 11801
EIA TIA 568A ENHANCED CAT 5 xxxxxxFT
Construction:-
Conductor Size 24AWG x 4Pair
Construction Bare Solid Conductor
Conductor Diameter (mm) 1 / 0.540+/-0.008
Insulation Average Thickness (mm) 0.260
Minimum Thickness (mm) 0.250
Diameter (mm) 1.060 +/- 0.040
Material FRPE for CMR
Co
lour 1. Blue x White/ Blue
#06-02 Hiap Huat House
Singapore 339940
Tel No : ( 65 ) 538 8628
Fax No : ( 65 ) 538 8636
Page 1 of 2
KRONE Premis
NET
HIGHWIRE BRONZE C5e FTP 24AWG 4 Pair CM Solid
Electrical & Physical Properties:-
Rating Temperature / Voltage 75c 300V
Conductor Resistance 93.8 Ohm/ Km/ 20c Max.
Dielectric Strength AC 1.5 KV/ Min.
Spark Test 2.5KV
Insulation Unaged Tensile Strength 1200 PSI Min (0.84 Kg/ mm Square)
Elongation 100 % Min
Aged Tensile Strength Unaged Min 75% (100c x 48Hours)
Elongation Unaged Min 75% (100c x 48Hours)
Jacket Unaged Tensile Strength 2000 PSI Min (1.41 Kg/ mm Square)
Elongation 100 % Min
Aged Tensile Strength Unaged Min 85% (100c x 240Hours)
Elongation Unaged Min 50% (100c x 240Hours)
Insulation Shrinkback 150m/m, 121+/-1c x 1Hour </= 9.5m/m
Cold Bend Test -20c x 4Hours, No Crack
Flame Test CM
Mutual Capacitance 56 PF/ M Max
A.C. Leakage Current through Overall Jacket A.C. 1500V </= 10mA
D.C. Resistance Unbalance 5% Max
Pair-to-Ground Capacitance Unbalance 3300 pF/ Km Max
Impedance 350 MHz 85~115 Ohm
Structural Return Loss 350 MHz 10.6 dB Min