23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 1 of 9
December 2001
Notes on the use of hand-held test devices for
installation of the KRONE Cat.6
K
K
M
M
8
8p
p
r
r
o
o
d
d
u
u
c
c
t
t
s
s
§ FLUKE DSP 4000 / 4100 / 4300
§ MICROTEST OMNIScanner2™
Includes:
§ 2 interface adapters
§ one set Personality module DSP-PM01
for KRONE KM8 (this is included in the standard delivery)
§ PM02 to PMxx are not relevant for measurement of the KRONE KM8
Note:
§ FLUKE DSP 4300 with new accessories (channel Cat.6 test head) is in preparation!
23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 3 of 9
December 2001
Cat 6/5e Channel Adapter DSP-LIA012S:
§ Contains two interface adapters for use with the DSP 4000 family
Basic Link Adapter:
§ DSP-LIA041S KRONE basic link adapter set for KRONE HighBand
§ This adapter cannot be used with the KM8
Required Settings:
§ Cable type
§ Category 5e, 6 or 7
§ UTP or STP
§ NVP´s (nominal velocity propagation) are in general already set as instrument default values;
otherwise see the table below
§ Measurement of shield influence: Yes / No (generally the choice is "No")
NVP settings for KRONE cables:
Cable Order No. NVP *
KRONE Cat 7 S-STP 7053 3 062-25 0.80
KRONE Cat 6 S-STP 7053 2 062-25 0.80
KRONE Cat 6 FTP 7053 2 021-04 0.68
KRONE Cat 6 UTP 7053 2 001-00 0.68
KRONE Cat 5e S-FTP 7053 1 052-25 0.66
KRONE Cat 5 FTP 7053 1 021-04 0.68
Scanlink PC Software: Software V 7.0
Accessories:
§ Permanent Link Interface Adapter 8262-38:
Includes:
§ 2 interface adapters, suitable
§ for the KRONE KM8
23
Notes on the use of hand-held test devices for installation of the KRONE Cat.6 KM8 products Page 5 of 9
December 2001
Cat 6/5e Channel Adapter 8262-02:
Basic Link Adapter:
§ 8262-22: KRONE Basic Link Adapter Set for the KRONE HighBand
§ This adapter is not recommended for the KM8
Required settings:
§ Type of cable
§ Category 5e, 6 or 7
§ UTP or STP
§ NVP´s (nominal velocity propagation) are in general already set as instrument default values;
otherwise see the table below
NVP settings for KRONE cables:
Cable Order No. NVP *
KRONE Cat 7 S-STP 7053 3 062-25 0.80
KRONE Cat 6 S-STP 7053 2 062-25 0.80
KRONE Cat 6 FTP 7053 2 021-04 0.68
KRONE Cat 6 UTP 7053 2 001-00 0.68
KRONE Cat 5e S-FTP 7053 1 052-25 0.66
KRONE Cat 5 FTP 7053 1 021-04 0.68
KRONE Cat 5 UTP 7053 1 001-00 0.68
KRONE C6 TrueNet UTP 7052 2 110-00 0.70
KRONE C5e TrueNet UTP 7052 1 110-00 0.70