POWERWORX
®
Power Distribution Products
www.adc.com • +1-952-938-8080 • 1-800-366-3891
Table of Contents
Introduction ..................................................................................................................................................1
PowerWorx
®
GMT 60e Series
Ordering Information ..................................................................................................................................2
Specifications ..............................................................................................................................................3
PowerWorx DSX PDP
Ordering Information ..................................................................................................................................4
Specifications ..............................................................................................................................................4
PowerWorx Traditional GMT Series
Ordering Information ..................................................................................................................................5
Specifications ..............................................................................................................................................6
Drawings and Sample Configurations ........................................................................................................7
PowerWorx Uninterrupted Power GMT Series
Ordering Information ..................................................................................................................................8
Drawings and Sample Configuration ..........................................................................................................8
Specifications ..............................................................................................................................................9
PowerWorx SuperFilter
™
GMT Series
Ordering Information ................................................................................................................................10
Specifications ......................................................................................................................................11-12
PowerWorx SuperPower
™
GMT Series Fuse Panels
Ordering Information ................................................................................................................................13
Ring Lug Kit ..............................................................................................................................................26
TPA Fuses – Alarm Indicator......................................................................................................................26
www.adc.com • +1-952-938-8080 • 1-800-366-3891
Table of Contents
PowerWorx
®
Advantage Series
™
Platform
Ordering Information ................................................................................................................................27
Specifications ............................................................................................................................................28
Drawings and Sample Configurations ......................................................................................................29
Accessories for Advantage Series
™
Carling Breakers ....................................................................................................................................30
Circuit Breaker Fingerguards..................................................................................................................30
Compression Lugs ................................................................................................................................30
Input Power Terminal Block Cover ........................................................................................................30
Output Power Terminal Block Cover......................................................................................................30
TPC Fuses/Fuse Holder ..........................................................................................................................30
TPC Fuse Holder Adapter ......................................................................................................................30
Index........................................................................................................................................................31-32
As networks and the variety of powered network
devices grow, so does the need for reliable power
distribution and protection in multimedia
broadband networks. ADC’s PowerWorx power
distribution products have been engineered from
the ground up to properly protect and distribute
power to valuable, revenue-generating network
equipment.
Up to 300 Amps/BUS
Advantage Series
™
Fuse and Circuit Breaker Platform
•
Fuse Panel
Without Filter
With Filter
SuperFilter
™
GMT Panel
•
Choose Platform
Circuit Breaker
Panel
Up to 100 Amps/BUS
Select Series
™
Circuit Breaker Platform
•
Choose Maximum
Input Amperage
Up to 100 Amps/BUS
(GMT, KLM, TPA Combo Fuses)
SuperPower
™
GMT Panel
(GMT Fuses)
•
Select Series
www.adc.com • +1-952-938-8080 • 1-800-366-3891
An Economical Alternative
As networks and the variety of powered net-
work devices grow, so does the need for reliable
power distribution and protection in multimedia
broadband networks. ADC's PowerWorx has
been engineered from the ground up to properly
protect and distribute power to valuable, rev-
enue-generating network equipment.
PowerWorx GMT 60e Series panels set a new
standard – delivering the power and the protec-
tion that service providers need. So if your net-
work needs power that works, use PowerWorx.
PowerWorx GMT 60e Series fuse panels deliver
power to valuable, revenue-generating network
equipment located in broadband multiservice
networks. The GMT 60e Series accepts input
power up to 60 Amps per bus. Up to 15 Amps
per fuse position is standard.
PowerWorx panels are independently tested to
comply with the industry's highest standards,
including CE, UL, CSA, and NEC 2002. In addi-
tion, the GMT 60e Series is backed by a five-year
warranty.
Flexible PowerWorx configurations suit most
every network application. Panels can be mount-
ed into 19-inch (48.3 cm), 23-inch (58.4 cm),
Electronic Industries Association (EIA) or Western
Electric Company (WECO), and 600 mm racks.
User-friendly ”upside down“ fuse holders and
STANDARDS:
PHYSICAL
Dimensions (HxWxD):
Weight:
Rack Mounting Width:
Rack Unit Spacing:
Housing Material:
Housing Finish:
POWER
Fuse Capacity*:
Panel Capacity:
Operating Voltage:
Power Dissipation:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Feed Connection:
Output Feed Connection:
Grounding:
ENVIRONMENTAL
Storage Temperature:
Operating Temperature:
Operating Humidity:
Operating Altitude:
WARRANTY
Meets UL, NEC 2002, CSA, and CE standards
Standard Access: 1.75" x 17.12" x 3.0" (4.44 x 43.48 x 7.62 cm)
Dimensions do not include depth of power connectors, alarm lamps
or fuses.
Approximately 4 lbs. (1.8 kg)
Products
PowerWorx
®
DSX PDP Series
Ordering Information
4
www.adc.com • +1-952-938-8080 • 1-800-366-3891
Primarily used to power LEDs in DSX modules, the PDP Series is also used to power auxiliary equipment
such as intraoffice and bridging repeaters as well as communication panels. Features two-hole
compression lug-style power input terminals, field-replaceable, high brilliance red LEDs to ensure panel
uptime and enhanced fuse visibility with "upside down" installed GMT fuse holders. Panel is compliant
with NEBS Level 3, UL, NEC 1999 and CSA.
GMT Fuses
Input power:
Bus amperage:
Remote alarm contact
(resistive load):
Local alarm indicator:
GMT Fuses:
-42 to -56 Vdc (no strapping required)
60 Amps maximum per bus
125V maximum
LED
3 Amps maximum per fuse
Electrical Specifications
20-Position Fuse Panel
Description Dimensions (HxW) Catalog Number Shipping
The PDP-FPCS201PWWXX is a Lower Amperage 1.75" x 19"/23" PDP-FPCS201PWWXX
Fuse Panel - Standard front and rear access with (4.5 x 48.3/58.4 cm)
3 amp maximum GMT fuse, two-hole
Products
PowerWorx
®
Traditional GMT Series
Ordering Information
5
www.adc.com • +1-952-938-8080 • 1-800-366-3891
With input power up to 65 Amps per bus, the
Traditional GMT Series eliminates the need to stock
varying amperage fuse panels. Fuse management is
simplified by accommodating up to 15 Amps of out-
put power per fuse position – without the need to
space fuses. A self-configuring voltage and polarity
feature allows a single panel to support most applica-
tions, providing ±24Vdc or ±48Vdc power.
Note: Panels ship with dummy fuses installed in all positions, one fused equipment designation card
holder and card, a voltage designation label, two 2-hole lugs per power bus, two ring lugs (for
grounding), and one designation pin holder per fuse holder.
Other custom configurations available. For more information call ADC at 1-800-366-3891
Description Catalog Number Shipping
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PWDP
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output.
Features dual power feed, 10/10 position fuse configuration,
power on and fuse alarm LED, wire wrap alarm contact
connection and EIA/WECO mounting option. Putty white.
PowerWorx Traditional GMT Series Fuse Panel - Standard PWX-001RGCSD10PSDB Standard
front and rear access with GMT fuse, two-hole compression
lug input and screw-down barrier terminal strip output.
Features dual power feed, 10/10 position fuse configuration,
8/07 • 105203AE
PowerWorx
®
Products
PowerWorx
®
Traditional GMT Series
Specifications
6
www.adc.com • +1-952-938-8080 • 1-800-366-3891
PHYSICAL
Dimensions (HxWxD)
Weight:
Rack Mounting Width:
Housing Material:
Housing Finish:
POWER
Fuse Capacity
1
:
Panel Capacity:
Operating Voltage:
Power Dissipation:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Feed Connection:
Output Feed Connection:
Grounding:
ENVIRONMENTAL
Two-post grounding accepts range of wire up to #10 AWG for single
connection; two-hole compression lug (stud-type) accepts wire up to
#2 AWG.
-45°C to 85°C
-5°C to 55°C
0% to 95%, non-condensing
Up to 13,000 feet (3.96 km)
Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC, and
CE standards
15 years
Fuse
Configuration
S10, D10
S10, D10
S20
S20
S40
S40
D20
D20
Output
Connector Type
Screw-Down
Set Screw
Screw-Down
Set Screw
Screw-Down
Set Screw
Screw-Down
Set Screw
Distance Between
Barriers Walls
0.325" (8.255 mm)
NA
0.325" (8.255 mm)
NA
0.20" (5.08 mm)
NA
0.20" (5.08 mm)
NA
1
Important Note: The fuse manufacturer recommends that fuses be continuously operated at no more
than 70% of their nominal current rating.
8/07 • 105203AE
PowerWorx
®
Products
7
www.adc.com • +1-952-938-8080 • 1-800-366-3891
PowerWorx
®
Traditional GMT Series
Drawings and Sample Configurations
Front
Rear
FUSE ALARM-A POWER-A FUSE ALARM-B POWER-B
FUSE INSTALLED UPSIDE-DOWNFUSE INSTALLED UPSIDE-DOWN
15 AMP MAX
PER FUSE
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Sample Catalog Number: PWX-001RGCSD20PWDP
Front
Total-Front-Access 10/10-Position Dual Power Feed
Sample Catalog Number: PWX-001FGCSD10PWDP
8/07 • 105203AE
PowerWorx
®
Products
PowerWorx
®
Uninterrupted Power GMT Series
Ordering Information
8
www.adc.com • +1-952-938-8080 • 1-800-366-3891
To ensure constant powering of fused network
equipment, the Uninterrupted Power GMT Series
features two input power feeds. If power to one
fails, the other serves as backup – taking on the
load of the failed circuit while maintaining its own
load. Schottky-steering diodes ensure panel uptime
until input power is restored, while a patent-pend-
ing heat dissipation design ensures safety. The
panel offers input power up to 60 Amps per bus.
Note: Panels ship with dummy fuses installed in all positions, one designation card holder and
card, one voltage designation label, two 2-hole lugs per power bus, two ring lugs (for ground-
ing), and one designation pin holder per fuse holder.
Each side (BUS) must be able to handle load if A or B is lost. (i.e. 30 amps or 60 total per side)
Description Catalog Number Shipping
PowerWorx Uninterrupted Power GMT Series Fuse Panel - PWX-011RGCSD10PWDP
Standard front and rear access with GMT fuse, two-hole
Approximately 11 lbs. (4.5 kg)
Using the universal mounting brackets, the standard fuse panel can be
flush- or recess-mounted into 19-inch (48.3 cm) and 23-inch (58.4 cm)
EIA and WECO racks. Using the mounting brackets, the total front
access fuse panel can be flush- or recess-mounted into 23-inch (58.4 cm)
EIA and WECO racks.
Cold-rolled 16 gauge steel. Polycarbonate protective coverprovided with
all panels.
Putty white or black powder-coat
0.2 to 15 Amps
60 Amps (maximum) per bus
-24 Vdc (-21 to -30 Vdc tolerance) or -48 Vdc (-42 to -56 Vdc tolerance)
40 watts maximum
Red LED indicates blown fuse. Green LED indicates power on.
Wire-Wrap alarm output contacts provided for audio, visual and remote
alarms.
1 Amp maximum
Two-hole compression-lug (stud-type) accepts range of wire up to 2 AWG.
Set screw barrel connector accepts range of wire up to 6 AWG. Panel
ships with two 2-hole lugs (accepting 6 AWG wire) per power bus.
Screw-down barrier terminal strip accepts range of wire up to 12 AWG.
Two-post grounding accepts range of wire up to #10 AWG for single
connection; two-hole compression lug (stud-type) accepts wire up to
#2 AWG.
-45°C to 85°C
-5°C to 55°C
0% to 95%, non-condensing
Up to 13,000 feet (3.96 km)
Meets UL, Telcordia (Bellcore), NEC 2002, CSA, NEBS Level 3, IEC,
and CE standardsLifetime
Fuse
Configuration
D10
Output
Connector Type
Screw-down
Max. Amperage
Per Fuse Position
15 Amps
Range Of Bare Wire
Accepted
12-22 AWG
Post/
Stud Size
#6-32
Distance Between
Barriers Walls
0.325" (8.255 mm)
8/07 • 105203AE
PowerWorx
®
Products
PowerWorx
®
SuperFilter
™
GMT Series
Ordering Information
10
www.adc.com • +1-952-938-8080 • 1-800-366-3891
Products
PowerWorx
®
SuperFilter
™
GMT Series
Specifications
11
www.adc.com • +1-952-938-8080 • 1-800-366-3891
PHYSICAL
Dimensions (HxWxD):
Weight:
Rack Mounting Width:
Housing Material:
Housing Finish:
POWER
Fuse Capacity:
Panel Capacity:
Operating Voltage:
Power Dissipation:
Fail Alarm Indicators:
Alarm Contact Connection:
Alarm Contact Relay:
Input Power
Input Feed Connection:
Output Power
Output Feed Connection:
Grounding:
1.75" x 17.12" x 10" (4.44 x 43.48 x 25.4 cm). Dimensions do not
include depth of power connectors, alarm lamps or fuses
T
B
R
T
N
B
A
T
T
A
R
T