The University of Sheffield
Electrical Machines & Drives Research Group
1
High Frequency Matrix Converter
High Frequency Matrix Converter
Nam Nguyen-Quang
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
2
• Background information
• Proposed converter
• Results to-date
• Conclusion
OVERVIEW
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
3
• Induction Heating (IH)
Î Basic Principles
Î Resonant Tanks
• Conventional Converters for IH
Î Current Source Inverter (CSI)
Î Voltage Source Inverter (VSI)
BACKGROUND INFORMATION
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
4
• A coil (work-head) creates a magnetic field, which
• Used with VSIs
Parallel resonant tank
• Low impedance at high
frequency
• Used with CSIs
C L
R
C
L
R
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
7
• Higher order resonant tanks have been used
• Most widely reported and useful is the LLC tank
INDUCTION HEATING – RESONANT TANKS
C
L
2
R
L
1
Î High impedance at
high frequency, can
be used with VSIs
Î Constant operating frequency
• Disadvantages
Î Effect of stray inductance: limit on frequency,
and physical cable length
Î High switching losses
Î Non-unity power factor, high harmonic
distortion
CONVENTIONAL CONVERTERS – CSI
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
11
• More emergent technology
• Power can be controlled by frequency, amplitude,
or phase angle (phase-shift) modulation
CONVENTIONAL CONVERTERS – VSI
C L
RV
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
0 1 2 3 4 5 6 7 8 9 10
S1
S2
S3
S4
Gate signals
14
• Phase angle (phase-shift) modulation: Many
variants, with or without lossless snubbers
CONVENTIONAL CONVERTERS – VSI
0 1 2 3 4 5 6 7 8 9 10
S1
S2
S3
S4
Gate signals
0 1 2 3 4 5 6 7 8 9 10
-30
-20
-10
0
10
20
30
Time (
μ
s)
Output voltage and current
Current
Voltage
0 1 2 3 4 5 6 7 8 9 10
S1
S2
S3
S4
0
10
20
30
Time (
μ
s)
Output voltage and current
Current
Voltage
15
• Using lossless snubbers, ZVS in both legs
CONVENTIONAL CONVERTERS – VSI
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
16
• Advantages
Î Many power control methods, some with ZVS
or ZCS, stray capacitances can be utilised
Î Stray inductances can be utilised
• Disadvantages
Î Large current harmonics at line side, non-unity
power factor
Î Bulky and unreliable DC link capacitor
CONVENTIONAL CONVERTERS – VSI
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
17
PROPOSED CONVERTER
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
19
• Topology
SINGLE PHASE MC – TOPOLOGY
V
A
V
BeBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
20
• The converter is expected to possess
Î Unity power factor, sinusoidal input current
Î ZVS and ZCS in one row, ZVS in other row
Î PWM power control over a wide range
SINGLE PHASE MC – TOPOLOGY
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
21
• Commutation problem: Modified voltage
commutation
The University of Sheffield
Electrical Machines & Drives Research Group
24
• Literature survey
• Reference system
• Simulations of single phase MC
RESULTS TO-DATE
eBook for You
The University of Sheffield
Electrical Machines & Drives Research Group
25
• Principles of induction heating
• Resonant converters for induction heating
• Analysis methods for resonant-mode inverters
• Utility interfaces for converters
• Other converters
RESULTS – LITERATURE SURVEY
eBook for You